Fire Alarm Control Panel
Detectors
Accessories
Automatic Extinguishing
Tools and Software
Analog Addressable Modules
Internet Enabled Fire Alarm System
As of the 1/1/12 Telefire will stop manufacture the GSA control panel Series.
Instead of the GSA series, Telefire offers its clients the new TSA series and its advantages.
The company is now negotiating with some new and significant clients over distribution agreements, as well as with new suppliers for exclusivity agreements.
A new Extinguishing Control Panel - The TSA-1000X has been launched.
the new detectors catalogue was added
A new ADR-3000 Brochure was added
Telefire is Proud to present the new Photoelectirc smoke detectors - the TFO-480.
Telefire is proud to present the new conventional dual-zone fire alarm system, the TSA-200.
Telefire's new conventional
dual-zone fire alarm system, the
TSA-200 has recieved the israeli standard.
A new product which can be connected to Telefire fire alarm systems - the FIREPRO aerosol generator.
A new article about the israeli standard for installation of fire alarm systems was added.
A new article about detectors has just been uploaded
Our new conventional control panel
The TSA-1000 has just received the European EN-54 standard
telefire

TSA-1000X

The TSA-1000X Electrical Automatic Control and Delay Device is designed in accordance with EN 54-2; EN 54-4; and EN 12094-1 Standards.

The TSA 1000X is a combined conventional (i.e. Non Addressable) Fire Alarm Control Panel and an Extinguishing Control and Delay Service.

It supports one flooding zone and four inputs, of which three are detector zones and one input is a programmable Detector/MCP/Auxiliary input. All four inputs can contribute to the extinguishing decision group (referred to in this manual also as the decision matrix).

The TSA-1000X has an internal and integral Power Supply/Charger, the PS_40W, designed and certified to EN 54-4.

In addition to being a Gas Extinguishing system, the TSA-1000X, due to its flexibility and optional features, can also control other extinguishing systems, such as water and aerosol systems.

Using Telefire's proprietary adapters, the extinguisher output can drive different extinguishing devices, such as solenoids, GCA, Detonators, etc.

Most inputs and outputs of the TSA-1000X are pre assigned and fixed function, and it is shipped with a default configuration and parameters. However, Input  No. 4 of the Main Board, output 4 of the Main Board and relay 6 of the EM083 expansion board can be programmed, and the ECD can be configured to adapt to different extinguisher systems and sites requirements (Using Telefire's proprietary adapters).